Safety guards and light curtains to shield moving parts
E-stop buttons near operator stations
Two basket and cart sets
Stainless steel quench tanks
1 tank w/ circulation pump, and plumbing for glycol quench (optional heater) 1 tank w/ circulation pump and plumbing for spray rinse capable of being filled for water quench
Seven second full or Five second half, basket immersion time
Necessary oven and quench tank thermocouples to meet AMS/BAC specification
Oven temperature ranges 225° – 1,010° F
Maximum overshoot 10° F
Oven temperature uniformity +/-10° F
Furnace and quench tank temperature retransmit outputs for data capture
NADCAP/ AMS/ BAC certification capable for aluminum alloy certification